  1. guyonthecouch

    name that deficiency!! seriously tho... name it..

    17 days into flower. System is a 6 site UC, water chilled to 66, day temps 79f - 64% humidity, night temps 70f - 50% humidity. RO water, 90 PPM going into system. nute mix per gallon: 1 ml Zone, 2 ml calmag, 4ml H&G A and B, 2.5 ml Crystal Burst (it's really comparable to Ginormous but a bit...
  2. guyonthecouch

    UC problem run... help me homies!!

    Also, just wanted to give a shout-out to rollinEndough for the spot-on assessment of my issue with my girls. Looks like they're gonna end up doin ok. I'm working at a lower EC on the other side of my room from the get-go this time and growth is straight-up explosive. I'm a believer in the...
  3. guyonthecouch

    UC problem run... help me homies!!

    but somebody killed killer, B!!!!! lol
  4. guyonthecouch

    UC problem run... help me homies!!

    "..... no ......"
  5. guyonthecouch

    UC problem run... help me homies!!

    about 50 days or so...
  6. guyonthecouch

    MIni spit! vs window box AC.. when you have many window box ac's..

    Window AC does not pump room air outside. The part that hangs outside the room blows outside air over the condenser coil to expel heat while the part inside the room blows room air over the cold evaporator coil. Completely seperated except in the case of larger ones that have a "fresh air"...
  7. guyonthecouch

    EZ-Clone chiller loop upgrade

    Here's the stainless version. Made it from about 9' of 3/8" stainless (316). It's almost twice the length of the original copper unit and cools 3 degrees lower, all other things equal. The stainless tubing runs just over $2.00 a foot from fab shops. It's pretty easy to bend yourself. Just...
  8. guyonthecouch

    "testing the waters"... of a water cooling setup. Some questions...

    What up, farmers. I'm finally ready to start migrating to a chiller-only setup with ice boxes, a water cooler CO2 genny, etc.. but I would like to start small with some existing equipment if possible prior to dropping coin for a big-boy chiller and big-boy pump. Looking for some advise from the...
  9. guyonthecouch

    EZ-Clone chiller loop upgrade

    Thanks for the tip, UCMENOW. I just picked up some 3/8" tubing in 316L stainless here locally and will be swapping out the copper tonight. It's still cooling like a champ tho. In this kind of setup, does the size of the submerged coil really matter all that much (by size, I mean length of the...
  10. guyonthecouch

    EZ-Clone chiller loop upgrade

    If you have a chilled UC system running, you can add a chilled look to you EZ clone for next to nothing. I made this one from copper just because it was readily available, but I'm going to replace it with stainless in a week or so. Here's what was needed: 1 - 5' coil of 3/8" soft copper...
  11. guyonthecouch

    What kind of filter on your chiller?

    If you are going to run a filter on the system, use that one. It's not too bad to clean, you just have to do it often. Put shut-off valves on either side of it so you can pull the filter with water still in the system.
  12. guyonthecouch

    What kind of filter on your chiller?

    The filters have a tube inside made of really fine mesh. They can become clogged easily and slow down the water flow. You have to clean them pretty often. I ran my chiller for a long time with no filter. It's not going to hurt the chiller or anything. It's present on the UC mostly to stop roots...
  13. guyonthecouch

    UC problem run... help me homies!!

    couple more... 37 days in these
  14. guyonthecouch

    UC problem run... help me homies!!

    lookin much better now. They were on the super weak mix for a little more than a week, then swapped for a slightly hotter mix, about 420 ppm with RO. They aren't very big but at least they are chunkin up a bit. thanks for the suggestions, homies
  15. guyonthecouch

    Struggling with UC Pre-veg, help appreciated

    looks nice. also looks like that was a super pain in the ass to drill your basket holes, lol! Your mods make that top fit like it was an actual lid but it looks like you may not be able to fill the water level high enough to flood the bottom of the baskets without being higher that the point...
  16. guyonthecouch

    Need Help With This Lighting Controller Flipbox

    The load on the relays at the time they are opening or closing is zero. The ballasts are off when the relay is triggered to open or close. How could 10A be deficient for this purpose? The conductors in the ballast cord are 16ga.... and they aren't energized at the time. To the OP, these...
  17. guyonthecouch

    Badass bulbs

    "badass". LOL! I bought two of their "badass blades" figure 8 wall fans. What a joke. Both stopped moving left to right after two runs. I took them back to the shop where I got them and they said every one of the units they sold had been returned. I know people like AN but my personal...
  18. guyonthecouch

    CO2 into a neg pressure bloom room.. help!!

    this seems to be able to do what I need, but it's pretty salty and likely overkill for what I need.
  19. guyonthecouch

    CO2 into a neg pressure bloom room.. help!!

    Got a slight dilemma here and am looking for some advice from the pros. I'm trying to add CO2 injection to a bloom room that is already setup and running. The room was setup to run under negative pressure and changing it to a sealed room, although technically an option, it not what I want to do...
  20. guyonthecouch

    UC problem run... help me homies!!

    not sure they're looking THAT much better. but i think a bit and they are definetley growing now so i think they are coming out of it.