Search results for query: *

  • Users: Olyver
  • Content: Threads
  • Order by date
  1. Olyver

    Agrowtek Controller System

    Agrowtek Controller System, GC-ProXL Climate & Hydroponics Controller I have the following for sale, prices indicated are the manufacturers wholesale prices for their distributors. 1 - GC-ProXL Climate & Hydroponics Controller w/basic climate sensor, 4 sensor ports, 16 outputs, 8 inputs...
  2. Olyver

    8 Table 16 Light Custom Automated Hydroponic Setup

    These are a few pics from a custom automated hydro setup using clay pellets and home-made halos. The res room has two 250 gallon reservoirs, each with an inline Leaded pump. Each one of the 4x8 flood/drain tables has 3/4" Y that goes to a return line to the res and a drain to waste line, for...
  3. Olyver

    Single Ballast Flips

    I have about 20 single ballast flips, they are $100 each. I will warranty them for 3 years and they are built with 600V rated lamp receptacles and 600V/40A relays.
  4. Olyver

    Large Scale Panels, Loadcenters, & Flip Boards

    Lighting Controllers
  5. Olyver

    Electrical Controllers and Electrical Rooms

    This thread is to showcase your custom electrical controllers, electrical rooms, wiring, etc.
  6. Olyver

    North American made Electronic Ballasts

    Would you buy an electronic ballast if it was assembled in North America. There is NO REASON why the same ballasts can't have pcbs etched and hand solder 90% of the components. Only pcb with smt components is the dimming module, and that can be pre-made, that module doesn't affect a electronic...
  7. Olyver

    Smoke Detectors in Grow Rooms

    A simple smoke detector wired to a relay module can shut off all the ballasts, fans, intake, etc. The smoke detectors can be daisy-chained together and wired to the Kidde Sm120X relay module with has NO and NC contacts. Wire it directly to contactors or relays and shut off all power. A couple...
  8. Olyver

    Three-Phase Loadcenters for 12, 18, and 24 Ballasts

    Forget CAP, Powerbox, Titan, EZ-Box, etc. I am working with a hydroponics distributor and we will have a 12, 18, and 24 ballast loadcenter for use with 120/208/240 3-phase power. The loadcenters will be configured with 120V or 240V style receptacles. Trying to keep the cost as low as possible...
  9. Olyver

    Electronic Dimming for Digital Ballasts

    No more selecting dimming features of 50%, 75%, 100% with a rotary switch. Microprocessor controlled to select dimming level at various times, all programmed with your settings. You can decide to dim your lights at various times of the day, automatically. For a 12 or 18 hour day, you can tell...
  10. Olyver

    Canadian Code Compliance for lighting controllers

    CEC 6-212: Enclosures for circuit breakers and externally operated switches shall not be used as junction boxes, troughs, or raceways for conductors feeding through or tapping off to other apparatus. This includes PLCs, relays, contactors, receptacles (especially these). This means NOT ONE...
  11. Olyver

    Multiple Pumps Controller

    Here's a pump controller that precisely controls five heavy duty submersible pumps. There are multiple timing cycles programmed via an internal PLC. The ON/OFF cycles are endless and different time cycles can be programmed for day and night feeding schedules. Probes and sensors can also be added...
  12. Olyver

    Lighting Controllers

    To all those who've sent me a PM for a lighting controller, I don't have enough posts to respond. If you'd like to know more, send an email to [email protected] Then I'll give you my website email. Wish I could post pics of every panel I've built..... Best Regards Olyver
  13. Olyver

    Three-Phase Panels

    Not all greenhouses are single-phase. Here are two three-phase panels with several options. RANCO digital temp controllers for high temp shutdown, SIEMENS PLC for time delays and auxillary sensor shutdown. Olyver
Top Bottom