You will want to use 6 ga 4 strand wire to go that distance,and going from main panel to installing a second panel you will want that extra ground wire in there so thats why i say use 4 strand.i know you said just a few lights plus equipment ,but a grower is never happy.you will want to add more shit eventually so go bigger.plus a 200 foot run has a sizable amp loss with smaller wire.
 
dsc00664-jpg.187889
 
look close at the plants around it bro..do you see anything?
All the neighbors are healthy as can be , even my headband and its really nute sensitive. I can take cuttings and the cuttings straighten right out good growth and all of the new growth is picture perfect. It's like hitting the reset button. That's why I started thinking it was a root problem. Here is a pic of a cutting off her after 3 weeks
Forgive me for the l.e.d. shot
IMG 20151105 184332570
IMG 20151105 184332570
 
You will want to use 6 ga 4 strand wire to go that distance,and going from main panel to installing a second panel you will want that extra ground wire in there so thats why i say use 4 strand.i know you said just a few lights plus equipment ,but a grower is never happy.you will want to add more shit eventually so go bigger.plus a 200 foot run has a sizable amp loss with smaller wire.
Im not an electrician but cant the ground wire go to a grounding rod? Save a few bucks on wire?
 
Well if your setting up a new breaker box or sub panel you want the 4 wire so you can bring both hot leads,the common,and ground into the new panel.theres always a cheaper way lol,but to do it safely and to carry enough load for future expansion it should be done in 6 ga or bigger wire.
My shop is about 160 feet away and i think we ran 180 feet of wire.i used direct burial aluminum wire which was a bit cheaper than copper.im good for 100 amps but im probably close to 80 now so with that whole 80% jazz im pretty much maxed out lol.
But yeah if your just putting in a few outlets 3 wire will be fine.but everything will need to be the same voltage on that curcuit.
 
Im pretty sure for a subpanel u can run 2 hots and a neutral to the main panel and for a ground just pound in a grounding rod and run a line to that from ur neutral block.
 
You will want to use 6 ga 4 strand wire to go that distance,and going from main panel to installing a second panel you will want that extra ground wire in there so thats why i say use 4 strand.i know you said just a few lights plus equipment ,but a grower is never happy.you will want to add more shit eventually so go bigger.plus a 200 foot run has a sizable amp loss with smaller wire.
Thank you Sixstring that's what I was afraid of. Of course I will need to go bigger in future. Always trying to add shit..
STR8
 
I think I only have room for one breaker,but I could upgrade my panel I guess..$$$ that's why I was going to wait on my electrician friend ,to see what he could do for me,on the low low..
STR8
 
I was thinking if I'm doing it I might as well do it right. Right?
So I want 220 ran out there and then split it to 220 for lights and or A/c,and 110 for all other outlets. So 6 gauge is it?
Thanks again guys..
I think I will call a different Electrician friend ,and see if he can help me.. It's a good thing working on pools,I meet all different labors.
STR8
 
Now look what we done to jimmy's thread,its all jacked up on power posts lol.plants lookin beastly bro,sum them mothers need flowered huh lol.
Im in my blind right now,pretty cold and quiet cept for 2 black squirrels
I almost threw the biggest one in flower lol..thought jaw she will drop a few dozen cuts for me in a week lol
 
Let's say I've got a couple z's I wanted to do something with, what's the easiest, cheapest, way to get something good out of it? I know I could just make up some butter but, I'm thinking more something smoke-able.
 