So im planning this setup for vertical setup under a double bed at only 90 cm height, with dual 400w lights, not ontop of eachother but sideways like the pic suggests.
The setup has 180cm width, 90cm depth, 90cm height.
Cooltubes of 125mm x 2.
http://i425.invalid.com/albums/pp336/Strawberryfileds/Strawberrys.jpg
So i am about to purcahse some fans and an odur removal system..or build one.
This fan and odor removal system needs to be quiet.
Im in a flat, next to people. Im not renting but i need this setup to be quiet.or quieten it !--maybe with carpet lining the room
??
-I also have a lot of stink in the drying room, so thinking
i need two or three odur removal systems.
Here are some ideas i was thinking about.
- in the diagram- should i have one fan pulling air through
both cooltubes, to ceiling space, with no "plant space" air going through the cooltubes.
Which fan? inline ok? if so 125mm or 150mm?
the cooltubes are 125mm.
Or two fans, one on each cooltube exuast?
Now for odur removal-
-have a filter at the back sucking air out through the filter and into living space??
what size filter what size fan should i go for??
Im thinking i might later on use a homemade co2 system (beer barrels) so might use the out take fan only once every three or so hours.
Im sure heat wont be a problem with cooltubes and a decent fan on the cooltube exaust.
Anyone want to run any ideas by me at all?
I would like this setup to be stealth and quiet as possible for a setup of this size, i think i can get it stealth in a study that is hardly used except for storing junk. and an old bed.
Thanks for any ideas.:joint:
iN SHORT-
-Will one big fan doing many things be quieter than a few doing different things?
-Are inline fans suitable for carbon filters?
-should i just use a good ozone gen for smell and small inline fans for cooltubes?- being a quiter way to remove smell and heat.
The setup has 180cm width, 90cm depth, 90cm height.
Cooltubes of 125mm x 2.
http://i425.invalid.com/albums/pp336/Strawberryfileds/Strawberrys.jpg
So i am about to purcahse some fans and an odur removal system..or build one.
This fan and odor removal system needs to be quiet.
Im in a flat, next to people. Im not renting but i need this setup to be quiet.or quieten it !--maybe with carpet lining the room
??
-I also have a lot of stink in the drying room, so thinking
i need two or three odur removal systems.
Here are some ideas i was thinking about.
- in the diagram- should i have one fan pulling air through
both cooltubes, to ceiling space, with no "plant space" air going through the cooltubes.
Which fan? inline ok? if so 125mm or 150mm?
the cooltubes are 125mm.
Or two fans, one on each cooltube exuast?
Now for odur removal-
-have a filter at the back sucking air out through the filter and into living space??
what size filter what size fan should i go for??
Im thinking i might later on use a homemade co2 system (beer barrels) so might use the out take fan only once every three or so hours.
Im sure heat wont be a problem with cooltubes and a decent fan on the cooltube exaust.
Anyone want to run any ideas by me at all?
I would like this setup to be stealth and quiet as possible for a setup of this size, i think i can get it stealth in a study that is hardly used except for storing junk. and an old bed.
Thanks for any ideas.:joint:
iN SHORT-
-Will one big fan doing many things be quieter than a few doing different things?
-Are inline fans suitable for carbon filters?
-should i just use a good ozone gen for smell and small inline fans for cooltubes?- being a quiter way to remove smell and heat.